Friday, January 17, 2014

Industrial Metal Detector FAQ’s


Industrial Metal Detector FAQ’s

1) What is the difference between wet and dry products?
Products that the metal detector recognizes as Dry (non-conductive) do not normally have any product effect and therefore would only require set-up/calibration only one time. The expected sensitivities are: whatever the Ferrous standard is the Non-Ferrous standard will be the approximately the same size, and the Stainless Steel standard will be approximately  one and a half times as big.
Products that the metal detector recognizes as Wet (conductive) do have product effect which has to be compensated for, to allow the best possible metal detection to be obtained.
The size of metal to be detected is determined by the amount of product effect caused by the product, and the expected sensitivities are: whatever the Ferrous standard is the Non-Ferrous standard will be approximately one and a half times as big, and the Stainless Steel standard will be approximately twice as big.
2) What is Product Effect?
Product Effects are the Electrical properties of your product; these are based on mass, density, temperature, conductance, and resistance just to name a few.
3) Why does a metal detector, on certain products, require frequent calibration / learn procedures?
These procedures are normally associated with what is termed wet / moist / reactive products.
These particular products can have a varying temperature / moisture / ingredient content which will create a different product effect than the original settings did.
To maintain the metal sensitivity specification a fresh calibration / learn procedure may be required to allow for this change and compensate for the change in product effect.
4) Is it possible to use one program for all products?
Yes, provided the products are similar. All dry products can normally use one program.
Reactive / moist / wet products can also use one program provided the products are of a similar type and you have set up the metal detector for the largest size.

5) Why won’t my metal detector calibrate / set-up for my Wet product?
If the product is small compared to the aperture size it will not create a large enough product effect to be accurately recognized, try bunching up multiple products to create a larger product effect.
6) Why occasionally does the metal detector not detect the required size of metal usually non-ferrous or stainless steel?
If the metal size to be detected is small and the product is wet/ reactive, it's possible the product effect is creating an amount of interference as great as the metal test sample does. A fresh calibration / learn might resolve this, or on a longer term, a more realistic metal size should be determined.
7) Why does the metal detector reject more than one pack on occasions?
This is usually associated with the product packs being too close together, was the metal in the back of the first package or the front of the second package?
Try to avoid having two packs within the search head at the same time.
A product registration photocell can minimize this effect.
8) The metal detector has lots of rejects (suspected false rejects).
ARE THEY REALLY FALSE REJECTS OR DO YOU HAVE VERY SMALL CONTAMINANTS?
Has product changed? Defrosted, heated up, spicier or totally different product. Try re-calibrating with the current product.
Is the belt clean? Check belt with no product running for large signals, either clean or change belt.

Saturday, August 3, 2013

Metal Detection


METAL DETECTOR

TROUBLESHOOTING GUIDE

 
There are many things that can interfere with the proper operation of a metal detector.  Easily 80% of "metal detector" problems are found to be caused by outside influences rather than the metal detector itself. Metal detector troubleshooting can be a frustrating experience, if you don’t check the following, most common causes of poor metal detector performance.

1. SYSTEMATICALLY NARROW YOUR SEARCH

While finding the exact source of the problem may take some time, it is relatively easy to narrow the search. If a metal detector starts to false reject, remove any product from the system and turn off the conveyor. If the detector continues to reject then the problem must be electrical interference or a problem with the metal detector itself. If the detector stops rejecting it is normally safe to assume that the detector itself is ok. Now start the conveyor and see if the detector begins to false reject. If it does then the problem is in the conveyor, possibly metal embedded in the belt or some type of ground loop problem. If all is still fine then begin to run product through the system. If the detector rejects on each product or on occasional product then the detector is not set up right for that product and adjustments must be made.

2. CHANGING OR INCONSISTENT PRODUCT

If a metal detector is set up to run frozen product and occasionally a semi-thawed product comes through the detector it will cause a false reject. This is because the detector is set to recognize the signal from the frozen product as a normal signal and since the signal from the semi-thawed product is different, the metal detector assumes that the signal is different because there is metal in the product.  This is true if any of the product characteristics change suddenly.

3. TWISTING OF THE METAL DETECTOR HEAD

It is very important for metal detectors to be mounted on a flat surface. An incline, decline, or vertical mount is not the important consideration as long as the surface is flat. An uneven surface will cause the metal detector body to twist or strain when the mounting bolts are tightened. This causes the metal detector to be unstable and can cause false rejects. Also, if the metal detector is mounted to a conveyor or support stand it is important for the feet of the conveyor to be firmly on the floor, if the conveyor or stand rocks it will create the same effect.

4. EXCESSIVE VIBRATION

Most metal detectors can handle quite a bit of vibration without a loss of sensitivity. Severe vibration, especially sudden jarring bumps or high frequency vibration can cause false rejects.  This problem will be amplified if the metal detector is running in the wet or conductive mode.

5. POWER LINE INTERFERENCE

Today's metal detectors are sophisticated electronic devices. They require a power source that is free from power line "noise". The noise, or voltage spike, can be caused by a variety of other equipment running on the same power source as the metal detector. The most common sources of these spikes are motors, heaters, sealers, or any other high current load. Metal detectors have some noise suppression circuitry built into them but if the spike is large enough it will cause the metal detector to false reject.

6. RADIATED SIGNAL INTERFERENCE

Because the metal detector is made of a transmitting and receiving antenna, it is susceptible to other signals that might be present in the area. False rejects can be caused by such things as V.F.D.’s (see handout) microwave type sealers or heaters, walkie-talkie type radios, or even faulty spark plug wires on a nearby forklift. Any machinery that can cause a burst of energy is a possible source of interference. The best method to minimize the interference is to place a shield around the possible source and electrically ground the shield.

7. GROUND LOOP INTERFERENCE

Many false rejects of a metal detector seem to have no obvious cause and can be very difficult to locate. One of the most common causes is a ground loop. When two pieces of metal make intermittent contact in the area of the metal detector it can cause a false reject. Because the metal detector is basically a transmitter and receiver, there is a very weak electrical field generated around the inspection head. The field will conduct itself through whatever is in its range, whether through the air, or through any metal in the area. As long as the field remains stable all is fine. If there is metal in the field that is making intermittent contact with another piece of metal, the shape of the field changes suddenly and the metal detector will give a false indication. Possible sources of ground loops are loose nuts or bolts, poorly designed reject devices, degenerating bearings in an idler or drive pulley, or even another piece of machinery bumping up against the metal detector system.

8. IMPROPER PROGRAMMING/SETUP

No metal detector can function properly if programmed incorrectly or if setup wrong. Correct programming or setup is essential.


SOURCES OF INTERFERENCE

TRANSMISSION TYPES:

LINE TRANSMISSION:

Today's metal detectors are sophisticated electronic devices. They require a power source that is free from power line "noise". The noise, or voltage spike, can be caused by a variety of other equipment running on the same power source as the metal detector. The most common sources of these spikes are motors, heaters, sealers, or any other high current load. Metal detectors have some noise suppression circuitry built into them but if the spike is large enough it will cause the metal detector to false reject.

RADIATED SIGNAL INTERFERENCE:

Since metal detectors are radio frequency sensing devices, it stands to reason that broadcast interference carried through the air, will be received by the sensing antenna. The detector has tuned circuits attached to the receiver that allow it to ignore signals that are outside of its operating frequency. However, some sources of broadcast EMI will have broadband (wide spectrum) characteristics and if significant energy lies at the same frequency as the detector's transmitter, then the interference will be passed through the system, usually resulting in unexplained or 'false' rejects.
This type of interference is very difficult to overcome and still allow product to pass through the aperture. 

SOURCES:

Typical sources of broadcast interference are: 
. Two-way radios- High frequency- Not usually a concern unless closer than 2 meters.
. Cell phones- Are very high frequency, and not a concern.
. Radio/TV broadcast- Constant and controlled frequency, not a concern.
. Switched motor controls (VFD, and Servo) - Serious problem due to wide spectrum noise source.

VARIABLE FREQUENCY DRIVES (VFD):

Variable frequency drives (a.k.a.: VSD, ASD) are a major source of EMI in industrial environments due to a general lack of regulation and the failure of field installers to follow recommended wiring and filtering methods outlined by the drive manufacturers. Naturally the drive manufacturers are not eager to stress the potential problems associated with their products.
 
Modern drives using IGBT switches for motor frequency control are very efficient due to their high switching speed. This has brought down the size and cost of drives and in turn, increased their usage. Unfortunately the high speed switching also results in much higher EMI and RFI is being generated by the sharper slopes of the drive square wave edges. The result is a wide spectrum of noise injected into the drive output cables, and (worse still) back into the plant power buss. These cables then act as broadcast antenna.
 
All drive manufacturers detail recommended installation procedures that are required in order to prevent excessive noise on both sides of the drive. These can sometimes be very elaborate and are usually ignored by the field installers. As the number of VFD controllers multiply in a plant, the chances of interference with other equipment also multiplies, and if the power buss is affected, the problem can show up in unexpected locations throughout the plant.
 
The problem of VFD radiation is very well documented by the drive manufacturers, and their publications should be referred to for more information.